Dimensions in mm EST distance back with operator SupraMatic HT BRH 2000 – 2250 3200 BRH 2255 – 2500 3450 BRH 2505 – 3000 4125 ITO 400 FU BRH 2000 – 2700 3840 BRH 2705 – 3000 4840 Required headroom SB* SupraMatic HT / ITO 400 FU Fitting behind the opening 100 / 120 with wicket door 100 / 120 with surface-mounted infill y = thickness of the surface- mounted infill y + 100 / y + 120 Fitting in the opening 120 / 140 with wicket door 120 / 140 with surface-mounted infill y = thickness of the surface- mounted infill y + 120 / y + 140 Clear opening height LH BRH = LH 2000 – 3000 Clear passage height LDH BRB < 4500  = BRH – 20 BRB ≥ 4500  = BRH – 60 with wicket door  = BRH – 70 Side space requirement SPB* ET 500 L at least 140 ET 500 S at least 250 Clear opening width LB BRB = LB 2250 – 6000 Swinging range AB with flush-fitting installation ET 500 L 35 ET 500 S 40 Fitting depth ZT-a/ZT-b ET 500 L 450 / 295 ET 500 S 400 / 245 Fitting dimensions Non-protruding up-and-over door ET 500 Horizontal view Fitting behind the opening Vertical view Fitting behind the opening EST Distance back SB Required headroom LH Clear opening height LB Clear opening width LDH Clear passage height LDB Clear passage width SPB Side space requirement BRH Nominal height (ordering size) BRB Nominal width (ordering size) ZT Frame depth AB Swinging range Explanation of dimensions EST SB BRH LDH SPB SPB BRB * An optional subframe is available for fitting situations without a lintel and/or sideroom. ZT-b ZT-a AB 26